| YVFYFFB series nitrile power flexible cable |
| |
|
1. Product features and uses
This product has cold resistance, soft, wear resistance, oil resistance and other characteristics, suitable for AC rated voltage 0.6/1KV and below with cold resistance, oil resistance and other special requirements of mobile electrical connecting cable, at present this product has been widely used in metallurgy, electric power, shipping, automobile manufacturing and other industries.
II: Product implementation standards
QJH009-2004.
GB12666-90 shall be followed for flame retardant performance test
III: Use characteristics
1. AC rated voltage: U0/U 0.6/1KV
* High operating temperature: 105℃
* Low ambient temperature: fixed laying-40℃
2. Cable installation laying temperature should not be lower than-25℃.
3. Allowable bending radius of cable: cable * small is 12 times of cable outer diameter
IV: Basic model and name
table 1
| model |
product name |
| YVFR |
NBR insulated and sheathed flexible power cables |
| YVFRP |
NBR insulated and sheathed copper braided shielded flexible power cable |
| ZR-YVFR |
Flame retardant nitrile insulated and sheathed flexible power cable |
| ZR-YVFRP |
Flame retardant nitrile insulated and sheathed copper braided shielded flexible power cable |
| YVFPR |
NBR insulated and sheathed shielded flexible cable |
| YVFRP2 |
NBR insulated and sheathed copper foil shielded flexible power cable |
| YVFRB |
NBR insulated and sheathed power flexible flat cable |
| YVFRPB |
NBR insulated and sheathed copper braided shielded flexible flat power cable |
| YVFB |
NBR insulated and sheathed mobile flat cable |
| YVFPB |
NBR insulated and sheathed copper braided shielded mobile flat cable |
| YVFP2B |
NBR insulated and sheathed copper foil shielded mobile flat cable |
| ZR-YVFRPB |
Flame-retardant nitrile insulated and sheathed copper braided shielded mobile flat cable |
| NH-YVFR |
Fire-resistant nitrile insulated and sheathed flexible power cable |
| NH-YVFRP |
Fire-resistant nitrile insulated and sheathed copper braided shielded flexible power cable |
| KYVFR |
NBR insulated and sheathed flexible control cable |
| KYVFRP |
NBR insulated and sheathed copper braided shielded flexible control cable |
| ZR-KYVFR |
Flame retardant nitrile insulated and sheathed flexible control cable |
| ZR-KYVFRP |
Flame retardant nitrile insulated and sheathed copper braided shielded flexible control cable |
| KYVFPR |
NBR insulated and sheathed shielded flexible control cable |
| KYVFRP2 |
NBR insulated and sheathed copper foil shielded flexible control cable |
| YVFP |
NBR insulated and sheathed shielded power cables |
| KYVFP |
NBR insulated and sheathed copper braided shielded control cable |
| ZR-KYVFP |
Flame retardant nitrile insulated and sheathed shielded control cable |
| ZR-KVFP2 |
Flame retardant nitrile insulated and sheathed copper foil shielded control cable |
| YVFP2 |
NBR insulated and sheathed copper foil shielded power cable |
| KYVFB |
NBR insulated and sheathed control flat cable |
| ZR-YFFB |
Flame-retardant nitrile compound insulated and sheathed mobile flat flexible cable |
| ZR-YFFPB |
Flame retardant nitrile compound insulated and sheathed copper wire shielded mobile flat flexible cable |
| YFFB |
Nitrile compound insulated and sheathed mobile flat flexible cable |
| YFFBP |
Nitrile compound insulated and sheathed copper wire shielded mobile flat flexible cable |
| YFFRB |
Nitrile compound insulated and sheathed mobile flat flexible cable |
| YFFRBP |
Nitrile compound insulated and sheathed copper wire shielded mobile flat flexible cable |
| YFF |
NBR insulated and sheathed cables |
| YFFP |
NBR insulated and sheathed copper wire shielded cable |
V: Code name and meaning
table 2
| code |
Code Meaning |
| YVF |
Nitrile cable series |
| P |
copper braid shield |
| R |
stranded conductor |
VI: Main technical indicators
1. DC resistance of finished cable conductor (Class R)(in accordance with GB3956) refer to Table 2 in Annex A.
2.The insulation resistance at 20 ℃ shall not be less than 50M/KM.
3. Finished cable withstand AC 50Hz 3.5KV/5min voltage test without breakdown.
VII: Basic cable specifications and structural parameters
| Core * Nominal section (mm2) |
conductor structure
(number of roots * diameter)
(B/R)
mm |
Cable * Large OD (mm) |
Reference Weight (kg/km) |
| YVFR |
YVFRP |
YVFR |
YVFRP |
| 1*2.5 |
51*0.25 |
4.0 |
- |
72 |
- |
| 1*4 |
82*0.25 |
6.0 |
- |
95 |
- |
| 1*6 |
123*0.25 |
7.0 |
- |
130 |
- |
| 1*10 |
204*0.25 |
9.5 |
- |
190 |
- |
| 1*16 |
323*0.25 |
11.0 |
- |
255 |
- |
| 1*25 |
513*0.25 |
12.0 |
- |
365 |
- |
| 1*35 |
722*0.25 |
13.5 |
- |
475 |
- |
| 1*50 |
1026*0.25 |
15.0 |
- |
670 |
- |
| 1*70 |
1406*0.25 |
17.0 |
- |
830 |
- |
| 1*95 |
486*0.50 |
19.0 |
- |
1200 |
- |
| 1*120 |
608*0.50 |
21.0 |
- |
1360 |
- |
| 1*150 |
760*0.50 |
23.0 |
- |
1654 |
- |
| 1*185 |
945*0.50 |
26.0 |
- |
2050 |
- |
| 2*2.5 |
51*0.25 |
10.5 |
11.5 |
159 |
205 |
| 2*4 |
82*0.25 |
12.5 |
13.5 |
230 |
290 |
| 2*6 |
123*0.25 |
14.0 |
15.2 |
276 |
336 |
| 2*10 |
204*0.25 |
18.0 |
19.2 |
413 |
475 |
| 2*16 |
323*0.25 |
22.0 |
23.5 |
567 |
670 |
| 2*25 |
513*0.25 |
24.5 |
25.5 |
833 |
933 |
| 2*35 |
722*0.25 |
29.0 |
30.2 |
1088 |
1288 |
| 2*50 |
1026*0.25 |
33.0 |
35.0 |
1297 |
1590 |
| 2*70 |
1406*0.25 |
38.0 |
39.0 |
1675 |
1900 |
| 2*95 |
486*0.50 |
41.0 |
43.0 |
2205 |
2500 |
| 2*120 |
608*0.50 |
48.0 |
50.0 |
2660 |
3000 |
| 2*150 |
760*0.50 |
52.0 |
54.0 |
3350 |
3750 |
| 2*185 |
945*0.50 |
57.0 |
59.0 |
4400 |
4820 |
| 3*2.5 |
51*0.25 |
12.0 |
13.0 |
210 |
270 |
| 3*4 |
82*0.25 |
13.0 |
14.0 |
295 |
365 |
| 3*6 |
123*0.25 |
14.8 |
15.8 |
375 |
455 |
| 3*10 |
204*0.25 |
19.0 |
20.0 |
559 |
639 |
| 3*16 |
323*0.25 |
22.0 |
23.0 |
770 |
870 |
| 3*25 |
513*0.25 |
26.0 |
27.0 |
1239 |
1349 |
| 3*35 |
722*0.25 |
33.0 |
34.1 |
1520 |
1640 |
| 3*50 |
1026*0.25 |
36.5 |
38.5 |
1970 |
2100 |
| 3*70 |
1406*0.25 |
40.5 |
42.5 |
2580 |
2790 |
| 3*95 |
486*0.50 |
48.5 |
50.5 |
3280 |
3500 |
| 3*120 |
608*0.50 |
53.0 |
55.0 |
4060 |
4380 |
| 3*150 |
760*0.50 |
58.0 |
60.0 |
5197 |
5597 |
| 3*185 |
945*0.50 |
63.0 |
65.0 |
6279 |
6700 |
| 3*4+1*2.5 |
82*0.25 |
14.5 |
15.6 |
300 |
370 |
| 3*6+1*4 |
123*0.25 |
16.0 |
17.2 |
400 |
490 |
| 3*10+1*6 |
204*0.25 |
21.0 |
23.0 |
590 |
690 |
| 3*16+1*10 |
323*0.25 |
25.0 |
26.0 |
850 |
950 |
| 3*25+1*16 |
513*0.25 |
30.5 |
32.5 |
1255 |
1410 |
| 3*35+1*16 |
722*0.25 |
33.5 |
35.6 |
1585 |
1790 |
| 3*50+1*25 |
1026*0.25 |
40.2 |
42.2 |
2066 |
2280 |
| 3*70+1*35 |
1406*0.25 |
47.2 |
49.5 |
2778 |
3080 |
| 3*95+1*50 |
486*0.50 |
50.0 |
52.2 |
2836 |
3126 |
| 3*120+1*70 |
608*0.50 |
53.0 |
55.5 |
4857 |
5207 |
| 3*150+1*70 |
760*0.50 |
57.0 |
59.5 |
5700 |
6090 |
| 3*185+1*95 |
945*0.50 |
66.0 |
69.0 |
7114 |
7514 |
| 4*4 |
82*0.25 |
14.0 |
15.0 |
325 |
400 |
| 4*6<, /P> |
123*0.25 |
17.5 |
18.5 |
421 |
500 |
| 4*10 |
204*0.25 |
22.0 |
23.0 |
635 |
720 |
| 4*16 |
323*0.25 |
24.0 |
25.0 |
8981010 |
|
| 4*25 |
513*0.25 |
31.0 |
32.0 |
1342 |
1490 |
| 4*35 |
722*0.25 |
34.0 |
35.0 |
1765 |
1900 |
Specific models are: YVF、YFF、YVFR、YFFR、YVFP、YFFP、YVFRP、YFFRP、YVFB、YFFB、YVFRB、YFFRB、YVFPR、YFFPR、YVFP2、YVFRP2、YVFPB、YFFPB、YVFBP、YFFBP、YVFBR、YFFBR、KYVF、KYFF、KYVFR、KYFFR、KYVFP、KYFFP、KYVFRP、KYFFRP、KYVFB、KYFFB、KYVFRB、KYFFRB、KYVFPR、KYFFPR、KYVFP2、KYVFRP2、KYVFPB、KYFFPB、KYVFBP、KYFFBP、KYVFBR、KYFFBR、ZR-YVF、ZR-YFF、ZR-YVFR、ZR-YFFR、ZR-YVFP、ZR-YFFP、ZR-YVFRP、ZR-YFFRP、ZR-YVFB、ZR-YFFB、ZR-YVFRB、ZR-YFFRB、ZR-YVFPR、ZR-YFFPR、ZR-YVFP2、ZR-YVFRP2、ZR-YVFPB、ZR-YFFPB、ZR-YVFBP、ZR-YFFBP、ZR-YVFBR、ZR-YFFBR、ZR-KYVF、ZR-KYFF、ZR-KYVFR、ZR-KYFFR、ZR-KYVFP、ZR-KYFFP、ZR-KYVFRP、ZR-KYFFRP、ZR-KYVFB、ZR-KYFFB、ZR-KYVFRB、ZR-KYFFRB、ZR-KYVFPR、ZR-KYFFPR、ZR-KYVFP2、ZR-KYVFRP2、ZR-KYVFPB、ZR-KYFFPB、ZR-KYVFBP、ZR-KYFFBP、ZR-KYVFBR、ZR-KYFFBR、YVFX、YFFX、YVFRX、YFFXR、YVFXP、YFFXP、YVFXRP、YFFXRP、YVFXB、YFFXB、YVFXRB、YFFXRB、YVFXPR、YFFXPR、YVFXP2、YVFXRP2、YVFXPB、YFFXPB、NH-YVF、NH-YFF、NH-YVFR、NH-YFFR、NH-YVFP, NH-YFFP, NH-YVFRP, NH-YFFRP, NH-YVFB, NH-YFFB, NH-YVFRB, NH-YFFRB, NH-YVFPR, NH-YFFPR, NH-YVFP2, etc. Withstand voltage 300/500V, 300/300V, 450/750V, 0.6/1KV.
Note: XX is added before the model number of flame retardant products, and flame retardant ZR, ZA, ZB, ZC, ZRA, ZRB, ZRC, ZBN, ZCN, ZAN, ZN, ZRN, low smoke and low halogen smoke resistance ZL, ZD, ZLW, ZWD, ZRD, ZRW are used to indicate armored products. XX is added at the lower corner after the model number of products, and steel tape armor 22, 29 and thin steel wire armor 32, 132 are used. Add ia, I, ZRI, IZ is intrinsic safety, add NH is fire resistance, add (T, D) is twisted form, shielding: P copper mesh shielding, P1 tin plating shielding, P2 copper foil shielding, P3 aluminum foil shielding, PL aluminum foil shielding, P22 shielding belt armor, P2/22 copper foil shielding belt armor
|
Our company mainly produces: ZR-VVRP, ZRC-VV22, ZRC-VVP, VVRP, VVR22, VV32, VV29, ZRC-VV29 Power cables, KVVP (T), ZRC-KVRP, ZA-KVRP, ZA-KVVR, ZA-KVVP 2, ZRC-KVVP 2 - 22, ZR-KVVP 2 - 22, ZN-KVVP, ZN-KVVR, ZRB-KVVP 2 - 22, ZRC-KVVP 22, KVVRP 22, JKVVP 32, ZR-JKVRP, etc. Control cables, ZRC-YJV, ZRB-YJV, ZRC-YJV 22, YJV 22, Cross-linked cables such as ZR-YJV, ZC-YJV, ZC-YJV 22, ia-K3YVP2, ia-K2YV, ia-K3YVP2/22, ia-K2 YVP2/22 intrinsically safe cables, WDZ-KVVP2, WDZ-KVVRP 2, DWZ-KVVP22, DWZ-KVVPR, WDZ-KVV 22, WDZB-KVVP, DWZB-KVVP, DWZC-KVVP, WDZC-KVVP and other low-smoke, low-halogen, low-smoke, non-halogen wires and cables, NH-VVR 22, NH-YJVR, NH-VVR, NH-FFP and other fire-resistant cables, HBF4, BB, HB glass fiber yarn braided KFF 46, DJF 46 PF 46 R, KF 46 F46 P2, KHFFP, KHFFR, KHFFRP, ZR-KHFFRP, ZRC-KFFP, ZRC-KFFRP, high temperature resistant cable, ZR-RVVP, RVVP, RVVP2, ZRC-RVVP, ZR-RVV and other shielded flexible cables, DJYPVRP 2, ZC-DJYP 1VP 1, ZA-DJYP 2 VR, ZA-DJYP 3VP 3, ZB-DJYPLVPL and other computer shielded signal cables, KX-HA-FF46 RP, KC-HA-HF46 P, JX-GB-VVP, TXFF46 R, SC-HPJB, EXVVRP, NCFFR, SX-GBVP, BX, EC, BC-HS-FFP, KX-GB-VVRP, EX-HA-FFRP, KC-GS-VVR, KX-HA-FFP, KC-HPJB, compensation cable, YGCRP22, YGGRP22, JGGRP22, KGGP2/22, YGG2/22P, KGGP22, KHFG, KHFGRP, ZR-KHFGP, KHFGP 2, ZR-KGGP, ZRC-KGGP, KGGR, ZRC-KGG, AGR, JHXG, ZR-JHXG, YGCB, YGCRB, ZR-YGCB, KGGRPB, YGCB-F46R, YGGRB, YGGB, YVFB, YVFPB, YVFRP, KGGRP 22, ZR-YZW, ZR-YH, ZR-YZ, ZR-YQW, ZR-YCW, ZR-YC, ZR-YQ, etc. Silicone rubber cables, Rubber jacketed cable, YVVP, YVVP2, YVVRP, YYVP, YYVP2, ZR-YVVP, ZR-YVVP2, ZR-YVRP, ZR-YYVP, ZR-YYVP2 instrument wire, QFR200, QVR 105, QFFR 200, QVVR 105, QFR 105, etc. 450 ℃ 500 ℃ pure nickel temperature wire, nickel plating high temperature wire, tin plating, silver plating thermal resistance lead wire, WRNNM2, WRR 2, WZPF 2, WRNK 2, WZPB 2, WZPM thermocouple, thermal resistance temperature transmitter, as well as automatic instruments and meters and other products, perennial high-priced acquisition of B. S, R thermocouple waste platinum rhodium couple wire and products, sincerely welcome your presence and guidance.